PROGRAMMABLE CONTROLLER FOR AIR HANDLING UNITS WITH CROSS FLOW HEAT RECOVERY APPLICATION MANUAL CODE 144SAV

Pagina 2

C-PRO MICRO SAVE APPLICATION MANUAL Page 10 Electric connections with 3-speed fans

Pagina 3 - Summary

C-PRO MICRO SAVE APPLICATION MANUAL Page 11 2.2.2 I/O configuration with 1 speed fans + speed variator c-Pro MICRO CAN with 2 A/O V+V (code CPU1S0C2

Pagina 4 - 1 GENERALITIES

C-PRO MICRO SAVE APPLICATION MANUAL Page 12 Electric connections with 1 speed fans + variator

Pagina 5 - 2 Applications

C-PRO MICRO SAVE APPLICATION MANUAL Page 13 2.3 Connection lay out for C-PRO MICRO CAN Below find the connection lay out of the C-PRO MIC

Pagina 6 - Page 6

C-PRO MICRO SAVE APPLICATION MANUAL Page 14 Connector 3: Connector for the analogue output (optional, not available in the day versions) Conn. Code

Pagina 7 - PG03 parameter

C-PRO MICRO SAVE APPLICATION MANUAL Page 15 2.4 Connection lay out for C-PRO EXP MICRO CAN Below find the connection lay out of the expansion with

Pagina 8 - 2.2 COMPLETE solution

C-PRO MICRO SAVE APPLICATION MANUAL Page 16 3 Network components and accessories

Pagina 9 - probe (0-5 V) (Optional)

C-PRO MICRO SAVE APPLICATION MANUAL Page 17 4 User interface 4.1 Display and keyboard Both control solutions (compact and complete) use the Vg

Pagina 10 - Page 10

C-PRO MICRO SAVE APPLICATION MANUAL Page 18 4.2 List of pages This paragraph presents the main pages and menus present in the application. The gener

Pagina 11

C-PRO MICRO SAVE APPLICATION MANUAL Page 19 The range of values accepted for the passwords is: -999 / 9999. If no action is taken on a menu after 4

Pagina 12 - Page 12

C-PRO MICRO SAVE APPLICATION MANUAL Page 2 Important Read these instructions carefully before installation and use and follow all recommendations re

Pagina 13

C-PRO MICRO SAVE APPLICATION MANUAL Page 20 4.2.5 RTC Menu This menu contains the functionalities linked to the system RTC: ⋅ the setting of the cl

Pagina 14

C-PRO MICRO SAVE APPLICATION MANUAL Page 21 4.2.7 Main OFF page The main OFF page changes depending on the reason why the unit is OFF.

Pagina 15

C-PRO MICRO SAVE APPLICATION MANUAL Page 22 COMPLETE VERSION Alarm icon: appears when there are active alarms. If all of them have bee

Pagina 16 - Page 16

C-PRO MICRO SAVE APPLICATION MANUAL Page 23 4.2.11 Log pages To display the alarms log, select HISTORIAN from the general menu or press ESC from th

Pagina 17 - 4 User interface

C-PRO MICRO SAVE APPLICATION MANUAL Page 24 5 Configuration parameters Below are listed all parameters managed by the application. A br

Pagina 18 - 4.2 List of pages

C-PRO MICRO SAVE APPLICATION MANUAL Page 25 Code Parameter description Default Min Max UM Menu Notes MAINTENANCE PM01 Max number

Pagina 19 - 4.2.4 Installer Menu

C-PRO MICRO SAVE APPLICATION MANUAL Page 26 Code Parameter description Default Min Max UM Menu Notes Level 3 MANUFACTURER MENU C

Pagina 20 - 4.2.6 Manufacturer Menu

C-PRO MICRO SAVE APPLICATION MANUAL Page 27 Code Parameter description Default Min Max UM Menu Notes ALARM PARAMETERS PA03 Enablin

Pagina 21 - 4.2.8 Main ON page

C-PRO MICRO SAVE APPLICATION MANUAL Page 28 5.2 COMPLETE solution list of configuration parameters Code Parameter description Default Min Max U

Pagina 22 - 4.2.10 Alarm pages

C-PRO MICRO SAVE APPLICATION MANUAL Page 29 Code Parameter description Default Min Max UM Menu Notes FANS PF01 Type of fans reg

Pagina 23 - 4.2.11 Log pages

C-PRO MICRO SAVE APPLICATION MANUAL Page 3 Summary Important ...

Pagina 24

C-PRO MICRO SAVE APPLICATION MANUAL Page 30 Code Parameter description Default Min Max UM Menu Notes VARIOUS PARAMETERS PH01 M

Pagina 25

C-PRO MICRO SAVE APPLICATION MANUAL Page 31 Code Parameter description Default Min Max UM Menu Notes FANS PF06 Minimum time tha

Pagina 26

C-PRO MICRO SAVE APPLICATION MANUAL Page 32 Code Parameter description Default Min Max UM Menu Notes ALARM PARAMETERS PA03 Enabli

Pagina 27

C-PRO MICRO SAVE APPLICATION MANUAL Page 33 6 REGULATIONS 6.1 State of the unit There are several unit switch-on/off procedures: 1) Via the

Pagina 28

C-PRO MICRO SAVE APPLICATION MANUAL Page 34 6.1.1 OFF state for alarm When the machine is active and an heavy alarm occurs the unit switches into th

Pagina 29

C-PRO MICRO SAVE APPLICATION MANUAL Page 35 Set the PH99 parameter to “YES”(1) and wait until it becomes “NO”(0) again on the display. The system aut

Pagina 30

C-PRO MICRO SAVE APPLICATION MANUAL Page 36 6.6 Functionality of the COMPACT control solution This control solution offers the base functionality

Pagina 31

C-PRO MICRO SAVE APPLICATION MANUAL Page 37 6.6.1.5 Fans status Each of the two fans can be in the following working states: 1. OFF: the fan is OFF

Pagina 32

C-PRO MICRO SAVE APPLICATION MANUAL Page 38 If the temperature T is between Tg and Tg + Tdiff (default 3°C, can be modified by parameter PF08) the cu

Pagina 33 - 6 REGULATIONS

C-PRO MICRO SAVE APPLICATION MANUAL Page 39 6.6.3.1 Cyclical defrosting with minimum temperatures The set point must be determined along with

Pagina 34 - 6.2 RTC setting

C-PRO MICRO SAVE APPLICATION MANUAL Page 4 1 GENERALITIES 1.1 Description The application is dedicated to the control and regulation of the A

Pagina 35 - 6.5 Programming key

C-PRO MICRO SAVE APPLICATION MANUAL Page 40 6.7 Features of the COMPLETE control solution Al functions of the COMPACT version are included in this

Pagina 36 - Page 36

C-PRO MICRO SAVE APPLICATION MANUAL Page 41 6.7.3 Fresh air intake damper It is possible to manage an optional motorised damper (can be enabled by p

Pagina 37

C-PRO MICRO SAVE APPLICATION MANUAL Page 42 Anti-freeze safety on hot water circuit (AL04) The anti-freeze mechanical thermostat (digital input DI7)

Pagina 38

C-PRO MICRO SAVE APPLICATION MANUAL Page 43 6.7.4.4 Heaters over temperature protection with automatic reset By setting the parameter PA16=1(hi

Pagina 39

C-PRO MICRO SAVE APPLICATION MANUAL Page 44 7 DIAGNOSTICS The application can manage a series of alarms relevant to the fans and the

Pagina 40 - 6.7.1 Post-Ventilation

C-PRO MICRO SAVE APPLICATION MANUAL Page 45 7.2 Alarms table Below is a list of all alarms managed by the application. The order of presentation is

Pagina 41 - 6.7.4 Heating

C-PRO MICRO SAVE APPLICATION MANUAL Page 46 7.4 Alarms log The controller record the ALARMS LOG in a non-volatile area of the memory organised as F

Pagina 42

C-PRO MICRO SAVE APPLICATION MANUAL Page 47 8 MODBUS VARIABLES The controller can be managed by a supervisor via Modbus protocol. The communi

Pagina 43

C-PRO MICRO SAVE APPLICATION MANUAL Page 48 Bit4=AL20, Bit5=AL21, Bit6=AL22, Bit7=AL23, Bit8=Free, Bit9=AL25, Bit10=AL26, Bit11=AL27, Bit12=AL28, Bit

Pagina 44 - 7 DIAGNOSTICS

C-PRO MICRO SAVE APPLICATION MANUAL Page 49 0x060D 1550 PT11a17_TypeDay[1] 0 0 1 0=Sunday,.. 6=Saturday R/W 0x060E 1551 PT11a17_TypeDay[2] 0

Pagina 45 - 7.3 General alarm relay

C-PRO MICRO SAVE APPLICATION MANUAL Page 5 2 Applications 2.1 COMPACT solution The picture above shows a principle layout. It is intended for

Pagina 46 - 7.4 Alarms log

C-PRO MICRO SAVE APPLICATION MANUAL Page 50 0x062A 1579 PF11_MinTimePostFan 30 0 999 sec R/W 0x062B 1580 PF12_SpeedFan_Confort_DI 3 1 3

Pagina 47 - 8 MODBUS VARIABLES

C-PRO MICRO SAVE APPLICATION MANUAL Page 51 0x064C 1613 PA13_ThermalResistorAlarm_Rele 1 0 1 R/W 0x064D 1614 PA15_LimitSitwchAlarm_Rele 1

Pagina 48

C-PRO MICRO SAVE APPLICATION MANUAL Page 52 0x066E 1647 PH55_Logic_DI5 0 0 1 0=NO, 1=NC R/W 0x066F 1648 PH56_Logic_DI6 1 0 1 0=NO, 1=NC

Pagina 49

C-PRO MICRO SAVE APPLICATION MANUAL Page 53 Application manual C-PRO MICRO SAVE Version 1.01 of November 2010 Code 144SAVEU0E01. This publication is

Pagina 50

OFFICES Evco Via Mezzaterra 6, 32036 Sedico Belluno ITALIA Tel. 0437-852468 Fax 0437-83648 [email protected] www.evco.it OVERSEES BRANCHES Control Fran

Pagina 51

C-PRO MICRO SAVE APPLICATION MANUAL Page 6 Electric connections with 3-speed fans Note: For driving the 3-speed fans (Digital output) set PG10=DO

Pagina 52

C-PRO MICRO SAVE APPLICATION MANUAL Page 7 Electric connections with 1 speed fans + variator Note: For driving the modulating fans (Analogue output

Pagina 53 - Page 53

C-PRO MICRO SAVE APPLICATION MANUAL Page 8 2.2 COMPLETE solution The picture above shows a principle layout, it is intended for indicating the p

Pagina 54

C-PRO MICRO SAVE APPLICATION MANUAL Page 9 2.2.1 I/O configuration with 3-speed fans c-Pro MICRO CAN with 2 A/O V+V (code CPU1S0C2V) c-Pro EXP MICRO