Evco EPH4EXP Hardware manual Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Evco EPH4EXP Hardware manual. EVCO EPH4EXP Hardware manual User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - HARDWARE MANUAL ver. 3.2

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Code 114CP3E324 page 1 of 116 c-pro 3 PROGRAMMABLE CONTROLLERS ENGLISH HARDWARE MANUAL

Pagina 2 - Important

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 10 of 116 2.3. Description c-pro 3 mega+ The following drawing shows th

Pagina 3

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 100 of 116 7.4. Vroom 7.4.1. Introduction Vroom is a new and innovativ

Pagina 4

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 101 of 116 7.4.3. Size Size in mm (in). Size Minimum Typical Maxi

Pagina 5 - 1. INTRODUCTION

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 102 of 116 8. ACCESSORIES 8.1. Programming kit EVIF20TUXI 8.1.1. Intr

Pagina 6

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 103 of 116 8.1.3. Size Size is in mm (in). 8.1.4. Connection to the

Pagina 7

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 104 of 116 The following table shows the meaning of the parts of the key

Pagina 8 - 2. DESCRIPTION

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 105 of 116 9. TECHNICAL DATA 9.1. Technical data Purpose of control: p

Pagina 9

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 106 of 116 The maximum lengths of the connecting cables are the followi

Pagina 10

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 107 of 116 Ambient conformity: ROHS 2002 / 95, WEEE 2002 / 96 / EC, REAC

Pagina 11

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 108 of 116 3 non optoisolated inputs, configurable via configuratio

Pagina 12

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 109 of 116 NTC analog inputs (10K Ω @ 25 °C, 77 °F) Kind of sensor:

Pagina 13

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 11 of 116 13 programming and debugging port 14 power supply 15 analog

Pagina 14 - 3. SIZE AND INSTALLATION

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 110 of 116 5 optoisolated digital inputs at 24 VAC / DC. 12 optoisol

Pagina 15 - 3.3. Size c-pro 3 NODE mega

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 111 of 116 PWM analog outputs (but the analog outputs 4 and 5 of c-pro

Pagina 16 - 3.4. Installation

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 112 of 116 6 outputs (electromechanical relays): • five 3 res. A @

Pagina 17 - 4. ELECTRICAL CONNECTION

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 113 of 116 3 non optoisolated ports: • 1 CAN port with CANbus commu

Pagina 18

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 114 of 116 Notes ______________________________________________________

Pagina 19

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 115 of 116 c-pro 3 PROGRAMMABLE CONTROLLERS Hardware manual ver. 3.2 PT

Pagina 20

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 116 of 116 EVCO S.p.A. Via Felt

Pagina 21

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 12 of 116 2.4. Description c-pro 3 NODE mega The following drawing show

Pagina 22

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 13 of 116 2.5. Description c-pro 3 EXP hecto and c-pro 3 EXP hecto+ The

Pagina 23

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 14 of 116 3. SIZE AND INSTALLATION 3.1. Size c-pro 3 hecto, c-pro

Pagina 24

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 15 of 116 3.3. Size c-pro 3 NODE mega 14 DIN modules; size in mm (in).

Pagina 25

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 16 of 116 3.4. Installation On DIN rail 35.0 x 7.5 mm (1.377 x 0.295 in

Pagina 26

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 17 of 116 4. ELECTRICAL CONNECTION 4.1. Electrical connection c-pro 3

Pagina 27

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 18 of 116 8 not connected The maximum length of the connecting cable

Pagina 28

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 19 of 116 - polarize the network of the RS-485 port (560 Ω, 0.25 W

Pagina 29

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 2 of 116 Important Important Read this document carefully before the ins

Pagina 30

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 20 of 116 NO2 normally open contact digital output 2 CO3 common digita

Pagina 31

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 21 of 116 Digital output 6 (electromechanical relay). Terminal Meaning

Pagina 32

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 22 of 116 For the settings about the analog outputs look at chapter 6 “C

Pagina 33

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 23 of 116 POWER SUPPLY Power supply. Terminal Meaning V≅ power supply

Pagina 34

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 24 of 116 4.1.2. Example of electrical connection of c-pro 3 hecto The

Pagina 35

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 25 of 116 4.2. Electrical connection c-pro 3 mega and c-pro 3 NODE mega

Pagina 36

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 26 of 116 8 not connected The maximum length of the connecting cable

Pagina 37

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 27 of 116 3 not connected 4 D0 = B = - (terminal 0 of the transceiver)

Pagina 38

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 28 of 116 MICRO-SWITCH Micro-switch to: - plug in the terminations of t

Pagina 39

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 29 of 116 For the settings about the CAN port look at chapter 6 “CONFIGU

Pagina 40

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 3 of 116 Index 1. INTRODUCTION ...

Pagina 41

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 30 of 116 NO8 normally open contact digital output 8 NC8 normally clos

Pagina 42

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 31 of 116 DI7 digital input 7 COM common digital inputs The maximum

Pagina 43

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 32 of 116 The maximum length of the connecting cables of the power sup

Pagina 44

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 33 of 116 4.2.2. Example of electrical connection of c-pro 3 mega The f

Pagina 45

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 34 of 116 4.3. Electrical connection c-pro 3 mega+ 4.3.1. Meaning of t

Pagina 46

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 35 of 116 8 not connected The maximum length of the connecting cable

Pagina 47

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 36 of 116 3 not connected 4 D0 = B = - (terminal 0 of the transceiver)

Pagina 48

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 37 of 116 MICRO-SWITCH Micro-switch to: - plug in the terminations of t

Pagina 49

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 38 of 116 For the settings about the CAN port look at chapter 6 “CONFIGU

Pagina 50

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 39 of 116 NO8 normally open contact digital output 8 NC8 normally clos

Pagina 51

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 4 of 116 7.3. Vtouch ...

Pagina 52

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 40 of 116 The maximum length of the connecting cables of the digital i

Pagina 53 - 5. USER INTERFACE

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 41 of 116 DIGITAL OUTPUTS Digital outputs 9 and 10 (electromechanical re

Pagina 54

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 42 of 116 For example: a CAN network can be made of a programmable con

Pagina 55 - 6. CONFIGURATION

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 43 of 116 ANALOG INPUTS Analog inputs 6, 7 and 8. Each analog input is c

Pagina 56

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 44 of 116 4.3.2. Example of electrical connection of c-pro 3 mega+ The

Pagina 57

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 45 of 116 To reduce the reflections on the signal transmitted

Pagina 58

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 46 of 116 4.4. Electrical connection c-pro 3 EXP hecto and c-pro 3 EXP

Pagina 59 - Vroom)

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 47 of 116 The maximum length of the connecting cables of the CAN port

Pagina 60

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 48 of 116 DIGITAL OUTPUTS In c-pro 3 EXP hecto+. Digital outputs 1, 2, 3

Pagina 61

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 49 of 116 The maximum length of the connecting cables of the PWM analo

Pagina 62

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 5 of 116 1. INTRODUCTION 1.1. Introduction c-pro 3 is a family of prog

Pagina 63

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 50 of 116 ANALOG INPUTS Analog inputs. Each analog input is configurable

Pagina 64

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 51 of 116 4.4.2. Example of electrical connection of c-pro 3 EXP hecto

Pagina 65

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 52 of 116 4.5. Additional information for electrical connection - do n

Pagina 66

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 53 of 116 5. USER INTERFACE 5.1. Keyboard The following table shows th

Pagina 67

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 54 of 116 CAN LED CANbus communication if it is lit, the device will be

Pagina 68

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 55 of 116 6. CONFIGURATION 6.1. Configuring a programmable controller

Pagina 69

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 56 of 116 To modify the real date and time operate as follows: 19. From

Pagina 70

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 57 of 116 6.1.2. Configuring a blind programmable controller The follo

Pagina 71

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 58 of 116 6.2. Configuring an I / O expansion The following procedures

Pagina 72

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 59 of 116 6.3. Configuring a device through an user interface (Vgraph,

Pagina 73

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 6 of 116 - 5 analog inputs configurable via configuration paramet

Pagina 74

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 60 of 116 6.4. List of configuration parameters 6.4.1. List of configu

Pagina 75

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 61 of 116 Parameters (1) AI3 - - - - - - - - - NTC kind of probe an

Pagina 76

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 62 of 116 Parameters (2) [ press button RIGHT to show it ] Password Indi

Pagina 77

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 63 of 116 Networks / CAN Bus [ press button RIGHT to show it ] TSEG2 1

Pagina 78

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 64 of 116 Networks / UART2 (1) Timeout 2 240 s 10 Modbus communicat

Pagina 79

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 65 of 116 Password Level 5: -32768 32767 - - - 0 value of the pas

Pagina 80

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 66 of 116 Diagnostic Math parameter available in read only modality Ma

Pagina 81

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 67 of 116 6.4.2. List of configuration parameters of c-pro 3 mega and o

Pagina 82

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 68 of 116 Parameters (1) AI3 - - - - - - - - - NTC kind of probe an

Pagina 83

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 69 of 116 Parameters (2) [ press button RIGHT to show it ] I/O Timeout

Pagina 84

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 7 of 116 c-pro 3 EXP hecto+ is available in blind version and can be use

Pagina 85

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 70 of 116 Parameters (2) [ press button RIGHT to show it; not available

Pagina 86

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 71 of 116 Parameters (2) [ press button RIGHT to show it ] Debug Baud -

Pagina 87

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 72 of 116 Networks / CAN Bus [ press button RIGHT to show it ] BTR(1) 1

Pagina 88

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 73 of 116 Networks / UART1 (1) Stop - - - - - - - - - 1 BIT Modbus c

Pagina 89

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 74 of 116 - - - - - - - - - ON enabling the password to gain acc

Pagina 90

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 75 of 116 Password Timeout 0 240 s 240 time-out of the passwords to

Pagina 91

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 76 of 116 Diagnostic Key Par parameter available in read only modality

Pagina 92 - c-pro 3 EXP hecto+

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 77 of 116 6.4.3. List of configuration parameters of c-pro 3 mega+ Subm

Pagina 93

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 78 of 116 Parameters (1) AI3 - - - - - - - - - NTC kind of probe an

Pagina 94

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 79 of 116 Parameters (1) AI Err Time 0 240 s 2 analog inputs time-o

Pagina 95

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 8 of 116 2. DESCRIPTION 2.1. Description c-pro 3 hecto and c-pro 3 hec

Pagina 96 - 7. USER INTERFACES

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 80 of 116 Parameters (2) [ press button RIGHT to show it ] En. Prg Level

Pagina 97 - 7.2.3. Size

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 81 of 116 Parameters (2) [ press button RIGHT to show it; not available

Pagina 98 - 7.3. Vtouch

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 82 of 116 Networks / CAN Bus MyNode 1 127 - - - 1 local (or of the

Pagina 99 - 7.3.3. Size

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 83 of 116 Networks / CAN2 Bus (4) MyNode 1 127 - - - 1 local (or of

Pagina 100 - 7.4. Vroom

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 84 of 116 0 65535 - - - - - - serial number of the first Bel

Pagina 101 - 7.4.3. Size

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 85 of 116 0 255 - - - - - - serial number of the sixth Belim

Pagina 102 - 8. ACCESSORIES

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 86 of 116 Networks / MP Bus Debug [press button RIGHT to show it ] (5) D

Pagina 103 - 8.2.2. Description

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 87 of 116 parameter available in read only modality errors counter

Pagina 104 - 8.2.3. Size

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 88 of 116 Networks / UART2 (2) Baud Rate - - - - - - - - - 9600 Modb

Pagina 105 - 9. TECHNICAL DATA

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 89 of 116 - - - - - - - - - ON enabling the password to gain acc

Pagina 106

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 9 of 116 2.2. Description c-pro 3 mega The following drawing shows the

Pagina 107

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 90 of 116 Diagnostic RTC parameter available in read only modality non

Pagina 108

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 91 of 116 Debug [ CAN bus ] rx parameter available in read only modalit

Pagina 109

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 92 of 116 6.4.4. List of configuration parameters of c-pro 3 EXP

Pagina 110

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 93 of 116 Parameters (1) AI3 - - - - - - - - - NTC kind of probe an

Pagina 111

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 94 of 116 Networks / CAN Bus [ press button RIGHT to show it ] TSEG1 0

Pagina 112

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 95 of 116 Debug [ CAN bus ] err parameter available in read only modali

Pagina 113

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 96 of 116 7. USER INTERFACES 7.1. Preliminary information The controll

Pagina 114

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 97 of 116 7.2.3. Size Size in mm (in). Size Minimum Typical Maxim

Pagina 115

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 98 of 116 7.3. Vtouch 7.3.1. Introduction Vtouch is a new and innovati

Pagina 116

EVCO S.p.A. c-pro 3 | Hardware manual ver. 3.2 | Codice 114CP3E324 page 99 of 116 7.3.3. Size Size is in mm (in). Size Minimum Typical Ma

Comentarios a estos manuales

Sin comentarios