PROCEDURE OF CONFIGURATION PARAMETERS PROGRAMMING
The configuration parameters programming can be done during the status "STOP" only, if there is not a corrupted memory data alarm.
There are two Levels of configuration (Level 2 is protected by password):
Level 1
Keep pushed T 8 and T 9 at the same time for 4 seconds at least: on the indicator DY 1 appear the
parameter "PA".
Push T 8 or T 9 to select the parameter to modify at Level 1.
Keep pushed T 10 and T 8 or T 9 to modify the selected parameter: after the modify release the key T 10 as last.
Level 2
From Level 1 push T 8 or T 9 to select the parameter "PA".
Keep pushed T 10 and T 8 or T 9 to set "-19": after the modify release the key T 10 as last.
Keep pushed T 8 and T 9 at the same time for 4 seconds at least: on the indicator DY 1 appear the first
parameter of Level 2.
Push T 8 or T 9 to select the parameter to modify at Level 2.
Keep pushed T 10 and T 8 or T 9 to modify the selected parameter: after the modify release the key T 10 as last.
How to leave the PROCEDURE
Keep pushed T 8 and T 9 at the same time for 4 seconds at least or wait 50 seconds without operate on
the keyboard (time-out exit) or stop and restart the instrument after about 1
second from the last modify.