EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 1 of 70 EVDRIVE03 Electronic expansion valves drivers ENGLISH U
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 10 of 70 3.2 Installation On DIN rail 35.0 x 7.5 mm (1.377 x 0.295 in) or
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 11 of 70 4 ELECTRICAL CONNECTION 4.1 Meaning of the connectors The follow
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 12 of 70 GND common analog inputs and free of voltage digital inputs AI1 a
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 13 of 70 CAN port line termination (not available in model EPD4BX3) Positio
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 14 of 70 Power supply Terminal Meaning V≅+ power supply device (not isolat
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 15 of 70 4.2 Example of electrical connection The following drawing shows
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 16 of 70 4.3 Additional information for electrical connection - do not op
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 17 of 70 5 USER INTERFACE 5.1 Preliminary information EVDRIVE03 is availa
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 18 of 70 STEP 2 LED auxiliary if parameter Ph80 = 0, LED status if it is li
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 19 of 70 6 OPERATION 6.1 Switch on and resynchronization At switch-on and
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 2 of 70 Important Important Read this document carefully before installing
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 20 of 70 The positioning speed depends on the operation mode: - during res
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 21 of 70 60 reserved 61 SH algorithm 6.3 Stand-by and operation mode sele
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 22 of 70 6.5 Analog positioner control The analog positioner mode permit t
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 23 of 70 6.7 Manual mode In manual mode (parameter Pr02 = 1), this permits
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 24 of 70 7 CONFIGURATION 7.1 Preliminary information A complete list of c
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 25 of 70 - if parameters alarm is active, check and correct all the para
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 26 of 70 or and page 8 page 9/11 or
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 27 of 70 page 15 page 17 or page 18
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 28 of 70 page 22 or page 23 or page
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 29 of 70 page 23 page 33 or and or and
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 3 of 70 Index 1 INTRODUCTION ...
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 30 of 70 For further information please consult the hardware manual of the
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 31 of 70 7.4 Configuring the device through the programming key EVKEY10 Th
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 32 of 70 4. Switch on the power supply of the device. 5. Operate as relat
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 33 of 70 7.7 List of configuration parameters The following table shows a
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 34 of 70 Pp04 -40.0 40.0 °C -40.0 User LOP temperature Pp05 -40.0 40.
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 35 of 70 Pa30 0 1 - - - - 0 Installer enable low pressure alarm 1 = ye
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 36 of 70 Pi00 0 19 - - - - 0 Manufact. type of refrigerant 0 = R-22 1
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 37 of 70 Pi07 0 28 - - - - 1 Costrutt. valve selection 0 = generic val
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 38 of 70 Pr06 0 9 - - - - 0 Manufact. enabling mode 0 = from free of
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 39 of 70 Pr51 Pr50 9999 step 1596 Manufact. maximum regulation steps Pr5
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 4 of 70 9.7 Algorithm status ...
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 40 of 70 Ph11 0 4 - - - - 1 Manufact. free of voltage digital input DI
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 41 of 70 Piu1 0 4 - - - - 1 Manufact. analog input AI1 function 0 = no
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 42 of 70 Piu2 0 2 - - - - 0 Manufact. analog input AI2 function 0 = no
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 43 of 70 Pia3 1 6 - - - - 1 Manufact. analog input AI3 probe type 1 =
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 44 of 70 Par. Min. Mas. Unità Default Menu Probe settings: offset Ofs
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 45 of 70 CANb 0 4 - - - - 1 Manufact. CAN baud rate 0 = 10K 1 = 20K 2
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 46 of 70 DrvM 0 5 - - - - - - - - User driving mode 0 = full step 2
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 47 of 70 AlgS - - - - - - - - - - - - - - - - User SH algorithm status
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 48 of 70 Psp 0.00 100.00 % - - - - User target position EnaS 0 1 -
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 49 of 70 8 SERIAL COMMUNICATION 8.1 Preliminary information It is possibl
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 5 of 70 1 INTRODUCTION 1.1 Introduction The drivers of the EVDRIVE03 seri
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 50 of 70 9 ALARMS AND ERRORS 9.1 Alarms and errors The system supports a
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 51 of 70 4 Invalid value for parameter PIA3 5 Invalid value for param
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 52 of 70 9.5 Probe error The probe alarm state is monitored every main cyc
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 53 of 70 9.7 Algorithm status Bit 10 of Alarm status (AlSt) is raised for
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 54 of 70 9.8.3 LOP When enabled (Pa40), this alarm is triggered when the e
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 55 of 70 10 ACCESSORIES 10.1 Programming key EVKEY10 10.1.1 Introduction
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 56 of 70 10.2 Programming kit EVIF20TUXI 10.2.1 Introduction EVIF20TUXI i
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 57 of 70 10.2.3 Size Size is in mm (in). 10.2.4 Connection to the Pers
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 58 of 70 10.3.2 Description The following drawing shows the aspect of the
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 59 of 70 10.3.3 Size Size is in mm (in). 10.3.4 Connection to the Pers
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 6 of 70 1.2 Summarizing table of the main features and available models Th
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 60 of 70 10.4 Backup module EPS4B 10.4.1 Introduction EPS4B is a backup m
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 61 of 70 10.4.3 Size Size is in mm (in). 10.4.4 Connection to the devi
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 62 of 70 11 TECHNICAL DATA 11.1 Technical data Purpose of the device: el
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 63 of 70 The maximum lengths of the connecting cables are the following: -
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 64 of 70 Analog inputs: 4 inputs of which 2 inputs (non optoisolated, which
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 65 of 70 0-5 V ratiometric analog inputs Input resistance: ≥ to 10K Ω. A
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 66 of 70 signalling LEDs. 128 x 64 pixel single colour (black with rearligh
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 67 of 70 1 non optoisolated programming port with MODBUS communication prot
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 68 of 70 Notes ___________________________________________________________
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 69 of 70 EVDRIVE03 Electronic expansion valves drivers User manual ver. 3.4
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 7 of 70 analog input 4 (suction pressure probe) 0-20 mA / 4-20 mA / 0-5 V /
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 70 of 70 EVCO S.p.A. Via Feltre 81,
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 8 of 70 2 DESCRIPTION 2.1 Description The following drawing shows the asp
EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344 page 9 of 70 3 SIZE AND INSTALLATION 3.1 Size The following drawing shows the
Comentarios a estos manuales