Terminals 1 and 2: Control input connector (Phoenix pull-out)
Conn. Abbrev. Description
1 12 V DC 12 V DC power supply
2 AO1 Impulse cut-off input
Terminals 3, 4, 5 and 6: Power connectors (FAST-ON)
Conn. Abbrev. Description
3 LOAD Load
4 LOAD Load (Neutral)
5 LOAD Neutral 230 V AC
6 LOAD Live 230 V AC
The cut-off module allows the control of single-phase fans with a maximum current equal to 5 A. The fan
module live feed must be the same as that feeding the controller.
If the C-PRO NANO has a DC power supply, then it is not possible to control the fans using the EVDFAN1.
Example:
V AC = 230 V
I max = 5 A
VA (max) = 230*5 = 1150 VA
W (max) = 230*5*cosφ = 1150 Watts if cosφ=1