1/13 DEEP FRYER WITH TIMER AND DIGITAL INPUTS OPERATING SPECIFICATIONS REV1.2

Pagina 2 - 1. USER INTERFACE

10/13 4.9. Peak Cut Input (In1) Input for the management of the maximum system power. Parameter P28 allows to configure the input polarity. I

Pagina 3 - 1.5. Modifying the count

11/13 - the buzzer does not ring if it has been previously silenced, the display shows “Pic” alternating with the default display, the alarm LED

Pagina 4 - 1.9. Silencing the buzzer

12/13 output can be activated at the start of the cycle following deactivation of the input. 4.11. Some regulation times 4.11.1. Example 1

Pagina 5

13/13 L1 flashing during pre-heat L1 on if pre-heat ended and probe 1 in [P8-P6,P8+P6] L1 flashing pre-heat terminated and if probe 1 is outsid

Pagina 6 - 2. CONNECTIONS LAYOUT

2/13 1. USER INTERFACE FUNCTION KEY FUNCTION B1 START B2 MELT B3 DISPLAY B4 TIMER B5 TIMER 1.1. Setting the set-point To access the

Pagina 7 - 3. PARAMETERS

3/13 • Press the [ENCODER] button or do not operate on the keyboard for 15 seconds 1.3. Timer start • Press the [B4] key for at least 1 secon

Pagina 8 - 4. REGULATION

4/13 1.7. Restoring the default parameters • Press the [ENCODER] button for 4 seconds, the PA label appears on the display. • Press the [ENC

Pagina 9 - 4.7. Fans

5/13 1.11. Displaying board temperature To access the procedure if probe 2 is enabled • Press the [B3] key, the Pb2 label will appear on the

Pagina 10 - 4.9. Peak Cut Input (In1)

6/13 2. CONNECTIONS LAYOUT EVC30S40 17891023456alimentazioneall'encoderK2com(Sonda 1)inK1carico 1carico 2+111213In1 In2+Termocoppie J(Sond

Pagina 11

7/13 3. PARAMETERS PAR. MIN. MAX. U.M. DEF WORK SET-POINT P0 0 1 --- 0 temperature unit of measurement 0 = °C 1 = °F P1 -25/-50 25/

Pagina 12 - 4.11.3. Example 3

8/13 4. REGULATION 4.1. Stop The display is on, LED L1 is off; the outputs are off, temperature regulation is not active. The temperature alar

Pagina 13

9/13 By pressing the [MELT] key, pass to • pre-heat mode, if the threshold P8 has still to be exceeded • preservation mode if threshold P8 has